  • BS-8FT

    This transducer is designed to measure strain in the inside or on the surface of thin concrete wall or on the surface of steel such as a wide flange beam.

    The BS-8FT strain transducer is designed to measure strain in the inside or on the surface of a thin concrete wall or on the surface of steel such as a wide-flange beam. A temperature measuring function enables it to simultaneously measure strain and temperature. Since the compact design measures only 80 mm in length, embedment applications are limited to concrete with comparatively small aggregates.
    Features
    ?? Self-temperature compensation type designed with a linear expansion coefficient approximated
        to that of concrete
    ?? Wide application range including measurement of strain on an earth retaining strut,
        steel sheet-pile and tunnel support
    ?? Usable for long-term measurement in place of a directly bonded strain gage
    PDF Download
    Specifications
    Strain Measurement
    Rated Capacity ??1000 ??m/m
    Nonlinearity Within ??2% RO
    Hysteresis Within??3% RO
    Rated Output ??1 mV/V (??2000??m/m) or more
    Temperature Measurement
    Rated Capacity -30 to 70 ??C
    Temperature Measurement Error ??0.5 ??C(-30 to 70 ??C)
    (Refer to Small-Sized Temperature Transducer BTS-100AT)
    Environmental Characteristics
    Safe Temperature Range -30 to 80??C
    Compensated Temperature Range -20 to 70??C
    Temperature Effect on Output Within??0.05%/??C
    Electrical Characteristics
    Safe Excitation Voltage 2 to 10V AC or DC
    Input Resistance (at 0??C) 350 ?? ??1%
    Output Resistance (at 0??C) 450 ?? ??1.6%
    Cable 4-conductor (0.3 mm 2 ) chloroprene shielded cable,
    6 mm diameter by 1 m long, bared at the tip
    Mechanical Properties
    Gage Mark Distance 80mm
    Safe Overload Rating 120%
    Apparent Linear Expansion Coefficient

    (11??1)??m/m/??C

    Weight

    Approx. 120 g