BS-25AT,25BT
These transducers are intended for measurement of the strain occurring inside concrete with comparatively large aggregates.
Strain transducers BS-25AT/BS-25BT are intended for measurement of the strain occurring inside concrete with comparatively large aggregates. Since a temperature measuring function is provided, these transducers can simultaneously measure strain and temperature.
The linear expansion coefficient is approximated to that of concrete to minimize temperature effects, thereby enabling measurement of external force-initiated strain and the strain corresponding to temperature stress.
Minimal damage against embedment vibrator and endures vibration initiated by the RCD method.
Strain Measurement |
Rated Capacity |
??500??m/m(AT) |
??1000??m/m(AT) |
Nonlinearity |
Within ??1.5% RO |
Within ??2% RO |
Hysteresis |
Within ??2% RO |
Rated Output |
??1 mV/V (??2000??m/m) or more |
??0.5 mV/V (??1000??m/m) or more |
Temperature Measurement |
Rated Capacity |
-30 to 70 ??C |
Measurement Error |
Within ??0.5??C (-30 to 70??C) |
(Refer to Small-Sized Temperature Transducer BTS-100AT) |
Environmental Characteristics |
Safe Temperature Range |
-30 to 80??C |
Compensated Temperature Range |
-20 to 70??C |
Temperature Effect on Output |
Within??0.05%/??C |
Electrical Characteristics |
Recommended Excitation Voltage |
2 to 10V AC or DC |
Input Resistance (at 0??C) |
350 ?? ??1% |
Output Resistance (at 0??C) |
450 ?? ??1.6% |
Cable |
4-conductor (0.5 mm 2 ) chloroprene shielded cable, |
11.5 mm diameter by 1 m long, bared at the tip |
Mechanical Properties |
Gage Mark Distance |
250mm |
Safe Overload Rating |
120% |
Apparent Linear Expansion Coefficient |
(11.5??0.6)??m/m/??C |
Weight |
Approx. 600 g |