GSAT-A-900
Rated Capacity:
+/- 900deg/s (+/- 15.708rad/s)
?? Compact and triaxial
?? High shock resistance
?? Most suitable for??posture measurement
?? AMA-A* can be mounted??on the top
Note: * AMA-A: Compact triaxial acceleration transducers
Applicable KYOWA instruments
?? EDX-200A(with CVM-40A mounted)
?? DIS-5010A
Performance |
Rated Capacity |
??900 deg./s (??15.708 rad/s) |
Nonlinearity |
Within ??0.5% RO |
Hysteresis |
Within ??0.5% RO |
Rated Output |
Approx. ??2.0 V |
Environmental Characteristics |
Safe Temperature Range |
-10??C to 60??C |
Compensated Temperature Range |
5??C to 40??C |
Temperature Effect on Zero Balance |
Within ??1.0% RO/??C |
Electrical Characteristics |
Safe Excitation Voltage |
??6.0 VDC with dual supply |
12 VDC with single supply |
Recommended Excitation Voltage |
??2.5 VDC to ??5.0 VDC with dual supply |
With single supply, refer to the instruction manual. |
No-load Output |
Within ??10% RO |
Cable |
Sensor: 9-conductor (0.04 mm 2 ) vinyl shielded cable, 2.7 mm diameter by approx. 7 m long |
Relay: 4-conductor (0.05 mm 2 ) vinyl shielded cables, 2.6 mm diameter by approx. 1 m long, terminated with connector plugs PRC03-12A10-7M |
(Shield wire is not connected to mainframe.) |
Mechanical PropertiesConnector |
Safe Overload Rate |
1,000% |
Safe Shock Resistance |
1,000G |
Transverse Sensitivity |
Within ??10% RO |
Dimensions |
See the dimensional drawing |