Able to Withstand against 10 Times Larger Overload than Rated Capacity by Built-in Overload Stopper
AS-TG series acceleration transducers have 3 incorporated miniature acceleration transducers to measure simultaneously 3 axial accelerations (front-rear, left-right, and up-down directions). Not only are interferences of AS-TG series among each axes little, but also AS-TG series can withstand against 10 times larger overload than rated capacity.
Moreover, it can be used also to 10,000,000 times of repetition loads.
 
     
        
					
    
      | Model  | 
      Rated Capacity 
(Reference Value)  | 
      Frequency Response 
 (at 23??C ) | 
    
    
      | AS-1TG   | 
      ??9.807m/s 2 (??1G)   | 
      DC to 40Hz ??5%  | 
    
    
      | AS-2TG   | 
      ??19.61m/s 2 (??1G)   | 
      DC to 60Hz ??5%  | 
    
    
      | AS-5TG   | 
      ??49.03m/s 2 (??1G)   | 
      DC to 100Hz ??5%   | 
    
    
      | AS-10TG   | 
      ??98.07m/s  2 (??1G)   | 
      DC to 150Hz ??5%  | 
    
    
      | AS-20TG   | 
      ??196.1m/s 2 (??1G)   | 
      DC to 250Hz ??5%   | 
    
  
	| Performance | 
	| Rated Capacity  | 
    See table above   | 
	| Nonlinearity  | 
    Within??0.1% RO  | 
	| Hysteresis   | 
    Within??0.1% RO  | 
	| Rated Output  | 
    0.5 mV/V (1000??m/m) or more  | 
	| Environmental Characteristics | 
	| Safe Temperature Range   | 
    -10 to 60??C   | 
	| Electrical Characteristics | 
	| Safe Excitation Voltage  | 
    6V AC or DC    | 
	| Recommended Excitation Voltage | 
    1 to 3V AC or DC   | 
	| Input Resistance  | 
    121???1.7%  | 
	| Output Resistance  | 
    121???1.7% | 
	| Cable  | 
    4-conductor (0.08mm  2 ) vinyl shielded cable diameter  3.2 mm by 5 m long, terminated with connector plugs   | 
	| (Shield wire is not connected to mainframe.)  | 
	| Mechanical PropertiesConnector | 
	| Safe Overload Rate  | 
    1000% (with stopper)  | 
	| Frequency Response Range   | 
     See table above  | 
	| Transverse Sensitivity   | 
    ??4%  | 
	| Weight  | 
    Approx. 110 g (Excluding cable)  | 
Note:
Measurement range of up-down direction is narrowed by 1G (9.807m/s 2 )
 because gravity acceleration is always applied to acceleration
transducers. In terms of AS-1TG, detected value exceeds rated capacity 
in positive side toward gravidy direction. Although AS-TG
acceleration transducers are not broked under safe overload rating,
 characteristics are out of warranty.