    Able to Withstand against 10 Times Larger Overload than Rated Capacity by Built-in Overload Stopper

    AS-TG series acceleration transducers have 3 incorporated miniature acceleration transducers to measure simultaneously 3 axial accelerations (front-rear, left-right, and up-down directions). Not only are interferences of AS-TG series among each axes little, but also AS-TG series can withstand against 10 times larger overload than rated capacity. Moreover, it can be used also to 10,000,000 times of repetition loads.
    Specification
    Model Rated Capacity
    (Reference Value)
    Frequency Response
    (at 23??C )
    AS-1TG ??9.807m/s 2 (??1G) DC to 40Hz ??5%
    AS-2TG ??19.61m/s 2 (??1G) DC to 60Hz ??5%
    AS-5TG ??49.03m/s 2 (??1G) DC to 100Hz ??5%
    AS-10TG ??98.07m/s 2 (??1G) DC to 150Hz ??5%
    AS-20TG ??196.1m/s 2 (??1G) DC to 250Hz ??5%
    Performance
    Rated Capacity See table above
    Nonlinearity Within??0.1% RO
    Hysteresis Within??0.1% RO
    Rated Output 0.5 mV/V (1000??m/m) or more
    Environmental Characteristics
    Safe Temperature Range -10 to 60??C
    Electrical Characteristics
    Safe Excitation Voltage 6V AC or DC
    Recommended Excitation Voltage 1 to 3V AC or DC
    Input Resistance 121???1.7%
    Output Resistance 121???1.7%
    Cable 4-conductor (0.08mm 2 ) vinyl shielded cable diameter
    3.2 mm by 5 m long, terminated with connector plugs
    (Shield wire is not connected to mainframe.)
    Mechanical PropertiesConnector
    Safe Overload Rate 1000% (with stopper)
    Frequency Response Range See table above
    Transverse Sensitivity ??4%
    Weight Approx. 110 g (Excluding cable)


    Note:
    Measurement range of up-down direction is narrowed by 1G (9.807m/s 2 )
    because gravity acceleration is always applied to acceleration
    transducers. In terms of AS-1TG, detected value exceeds rated capacity
    in positive side toward gravidy direction. Although AS-TG
    acceleration transducers are not broked under safe overload rating,
    characteristics are out of warranty.