Model |
Rated Capacity |
Natural Frequency(Approx.) |
PD-100GA |
10kPa |
60Hz |
PD-200GA |
20kPa |
110Hz |
PD-500GA |
50kPa |
230Hz |
PD-1KA |
100kPa |
400Hz |
PD-2KA |
200kPa |
700Hz |
Performance |
Rated Capacity |
See table above. |
Nonlinearity |
Within??0.3% RO |
Hysteresis |
Within??0.2% RO |
Rated Output |
1.5 mV/V (3000??m/m)??1% |
Environmental Characteristics |
Safe Temperature Range |
-10 to 70??C |
Compensated Temperature Range |
0 to 60??C |
Temperature Effect on Zero Balance |
Within??0.05% RO/??C (PD-100GA) |
Within??0.01% RO/??C (PD-200GA to 2KA) |
Temperature Effect on Output |
Within??0.5%/??C (PD-100GA) |
Within??0.03%/??C (PD-200GA to 2KA) |
Electrical Characteristics |
Safe Excitation Voltage |
15V AC or DC |
Recommended Excitation Voltage |
1 to 10V AC or DC |
Input Resistance |
350???1% |
Output Resistance |
350???1% |
Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
7.6 mm diameter by 5 m long, terminated with connector plug
|
(Shield wire is not connected to mainframe.) |
Mechanical Properties |
Safe Overload Rating |
150% |
Differential Pressure |
200% (PD-100 & 200GA) |
150% (PD-500GA & 1KA) |
125% (PD-2KA) |
Maximum Line Pressure |
2.94 MPa |
Natural Frequency |
See table above |
Weight |
Approx. 5 kg (not including cable) |
*To use for gas, contact us.
When A side is a high pressure plus output
B side is a high pressure minus output.
(Refer to A,B Dimensions)