LC-V
Compact and lightweight Accuracy: 1/2000
Compact and lightweight design facilitates installation
into existing facilities. While accuracy of 1/2000
is ensured, the hermetically-sealed structure with
inert gas filled in enables highly stable and reliable
measurement. (Patented)
?? Hermetically sealed structure with inert gas filled in
?? Service life: 10 million times or more
?? BISELCOM gage is used.
Model |
Rated Capacity |
Natural Frequency
(Approx.) |
Weight
(Approx.) |
LC-5TV |
50kN |
17kHz |
800g |
LC-10TV |
100kN |
16kHz |
1.3kg |
LC-20TV |
200kN |
15kHz |
2.6kg |
Performance |
Rated Capacity |
See table above |
Nonlinearity |
Within??0.05% RO |
Hysteresis |
Within??0.05% RO |
Repeatability |
0.03% RO or less |
Rated Output |
2.5 mV/V (5000??m/m) ??0.2% |
Environmental Characteristics |
Safe Temperature Range |
-20 to 80??C |
Compensated Temperature Range |
-10 to 70??C |
Temperature Effect on Zero Balance |
Within ??0.003% RO/??C |
Temperature Effect on Output |
Within ??0.003%/??C |
Electrical Characteristics |
Safe Excitation Voltage |
20V AC or DC |
Recommended Excitation Voltage |
1 to 10 VAC or DC |
Input Resistance |
350???0.5% |
Output Resistance |
350???0.5% |
Cable |
4-conductor (0.5 mm 2 ) chloroprene shielded cable,
8.5 mm diameter by 5 m long, with press-fit terminal for 4 mm |
(Shield wire is not connected to mainframe.) |
Mechanical Properties |
Safe Overload Rating |
150% |
Natural Frequency |
See table above |
Weight |
See table above |
Protection Rating |
IP67 (watertight type conforming to JIS C 0920) |