BER-A-110S
Stainless steel models can be manufactured for wave pressure measurement.
The BER-A-110S soil pressure transducers come with the cable attached in parallel to the pressure-sensing surface
Wear of the pressure sensing surface does not affect output or initial values.
Load cell-based design is less affected by bending effects.
Usable for pressure measurement of coal or grain in a silo
For pressure measurement of pulverulent bodies of approximately 15 mm in diameter
| Model |
Rated Capacity |
Load(rated capacity) |
| BER-A-100KP110S |
100kPa |
709N |
| BER-A-200KP110S |
200kPa |
1.4kN |
| BER-A-500KP110S |
500kPa |
3.5kN |
| BER-A-1MP110S |
1MPa |
7.1kN |
| BER-A-2MP110S |
2MPa |
14.2kN |
| Nonlinearity |
Within ??1% RO |
| Hysteresis |
Within ??1% RO |
| Rated Output |
1 mV/V (2000??m/m) or more |
| Environmental Characteristics |
| Safe Temperature Range |
-30 to 80??C |
| Compensated Temperature Range |
0 to 70??C |
| Temperature Effect on Zero Balance |
Within ??0.1% RO/??C |
| Temperature Effect on Output |
Within ??0.1%/??C |
| Electrical Characteristics |
| Safe Excitation Voltage |
10V AC or DC |
| Recommended Excitation Voltage |
1 to 5V AC or DC |
| Input Resistance |
350???2% |
| Output Resistance |
350???2% |
| Cable |
4-conductor (0.5 mm
2
) chloroprene shielded cable, |
| 10 mm diameter by 1 m long, bared at the tip |
| (Shield is not connected to the chassis.) |
| Mechanical Properties |
| Safe Overload Rating |
120% |
| Maximum Load |
See table above |
| Pressure Sensing Surface Diameter |
Approx. 95 mm |
| Material |
Stainless steel metallic finish (pressure sensing surface) |
| ZnC-plated MF (flange and cable outlet) |
| Water Pressure Resistance of Cable Outlet |
600kPa |
| Weight |
Approx. 2.2 kg |
* Can optionally be coated with anti-biofouling paint.