LCW-D-S/E-S
The Flat Washer-type Structure of Loadcell Well Suited to Rolling Mills.
The hermetically-sealed structure with inert gas filled in ensures a reliable and stable operation under harsh
conditions.
The flat washer type structure only requires processing of the screw nuts for installation to existing rolling mills.
?? Hermetically-sealed structure with inert gas filled in
?? Heat and oil resistant cable.
?? High reliability
| Model |
Rated Capacity |
Natural Frequency(Approx.) |
Weight(Approx.)* |
| LCW-D-1MNS |
1MN |
16kHz |
7kg |
| LCW-D-2MNS |
2MN |
14kHz |
15kg |
| LCW-D-3MNS |
3MN |
15kHz |
17kg |
| LCW-D-5MNS |
5MN |
16kHz |
20kg |
| LCW-E-1MNS |
1MN |
16kHz |
7kg |
| LCW-E-2MNS |
2MN |
14kHz |
15kg |
| LCW-E-3MNS |
3MN |
15kHz |
17kg |
| LCW-E-5MNS |
5MN |
16kHz |
20kg |
*not including cable
| Performance |
| Rated Capacity |
See table above |
| Nonlinearity |
Within??1% RO |
| Hysteresis |
Within??1% RO |
| Repeatability |
0.3% RO or less |
| Rated Output |
1 mV/V (2000??m/m) or more |
| Environmental Characteristics |
| Safe Temperature Range |
-20 to 100??C |
| Compensated Temperature Range |
-10 to 80??C |
| Temperature Effect on Zero Balance |
Within ??0.01% RO/??C |
| Temperature Effect on Output |
Within ??0.01%/??C |
| Electrical Characteristics |
| Safe Excitation Voltage |
15V AC or DC |
| Recommended Excitation Voltage |
1 to 10V AC or DC |
| Input Resistance |
350???1% |
| Output Resistance |
350???1% |
| Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
8 mm diameter by 15 m long, bared at the tip |
| (Shield wire is not connected to mainframe.) |
| Mechanical Properties |
| Safe Overload Rating |
150% |
| Natural Frequency |
See table above |
| Weight |
See table above |
| Protection Rating |
IP64 (Splashproof type conforming to JIS C 0920) |