LFM-A
Compact,High Sensitivity Center Hole Type of 6-component Force Transducers
Enables simultaneous measurement of 3 forces (Fx, Fy, Fz) in 3 axial directions orthogonal to the
transducer and 3 moments (Mx, My, Mz) around the axes.
An 8-channel measuring instrument amplifies the transducer's 8 output components in strain quantity
and calculates 6-component force.
In addition, real-time measurement is possible by connecting PC and PCD-300B. (Measurement
software PCD-6A is required.)
* The equation is described to the LFM-A manual
| Model |
Rated Capacity |
Rated Output |
Natural Frequency(Approx.) |
Natural Frequency(Approx.) |
| LFM-A-1KN |
FX ?? ??1000N
FY ?? ??1000N
FZ ?? ??1000N
MX ?? ??50N・m
MY ?? ??50N・m
MZ ?? ??25N・m |
FX ?? ??1.5mV/V
or more
FY ?? ??1.5mV/V
or more
FZ ?? ??1.8mV/V
or more
MX ?? ??4.0mV/V
or more
MY ?? ??4.0mV/V
or more
MZ ?? ??2.4mV/V
or more
|
5kHz |
160g |
| LFM-A-3KN |
FX ?? ??3000N
FY ?? ??3000N
FZ ?? ??3000N
MX ?? ??100N・m
MY ?? ??100N・m
MZ ?? ??50N・m |
FX ?? ??1.6mV/V
or more
FY ?? ??1.6mV/V
or more
FZ ?? ??1.6mV/V
or more
MX : ??2.4mV/V
or more
MY ?? ??2.4mV/V
or more
MZ ?? ??1.6mV/V
or more
|
5kHz |
360g |
*The Rated Output is an Interference Correction Further Output.
| Performance |
| Rated Capacity |
See table above |
| Nonlinearity |
Within ??0.5% RO |
| Hysteresis |
Within ??0.5% RO |
| Interference |
??1.5% RO (after correction by interference correction coefficient stated in Calibration Sheet) |
| Rated Output |
See table above |
| Environmental Characteristics |
| Safe Temperature Range |
-10 to 70??C (non-condensing) |
| Compensated Temperature Range |
Within ??0.05% RO/??C or less |
| Temperature Effect on Zero Balance |
Within ??0.05% RO/??C or less |
| Temperature Effect on Output |
Within ??0.05%/??C or less |
| Electrical Characteristics |
| Safe Excitation Voltage |
12V AC or DC |
| Recommended Excitation Voltage |
1 to 5V AC or DC |
| Input/Output Resistance |
350???3% |
| Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
6.6 mm diameter by 55 cm long, bared at the tip |
| (Shield wire is not connected to mainframe.) |
| Mechanical Properties |
| Mechanical Properties |
150% |
| Material |
Main unit LFM-A-1KN: Aluminum (metallic finish) |
| Main unit LFM-A-3KN: SUS (metallic finish) |
| Cover: Black anodic oxide coating aluminum |
| Cable holder: Anodic oxide coating aluminum |
| Weight |
See table above (not including cable) |
| Protection Rating |
IP40 |