LT-FH/FL
High Reliability, Airtight Structure, Selectable from a Wide Range of Rated Capacities.
LT-FH series enables continuous operation under
temperature as high as 150??C with no external
cooling. LT-FL series enable operation at ultra-low
temperatures ranging from -196??C .
?? Mechanical stopper that activates at 500% overload
*TEDS-installed versions can be manufactured. Inquiries are welcome.
| Model(FH) |
Model(FL) |
Rated Capacity |
Natural Frequency |
Weight |
| LT-50KFH |
LT-50KFL |
500N |
1.5kHz |
1.7kg |
| LT-100KFH |
LT-100KFL |
1kN |
2.6kHz |
| LT-200KFH |
LT-200KFL |
2kN |
4.1kHz |
| LT-500KFH |
LT-500KFL |
5kN |
5.0kHz |
2.0kg |
| LT-1TFH |
LT-1TFL |
10kN |
5.2kHz |
2.1kg |
| LT-2TFH |
LT-2TFL |
20kN |
5.8kHz |
2.4kg |
| LT-5TFH |
LT-5TFL |
50kN |
4.5kHz |
7.0kg |
| Performance |
| Rated Capacity |
See table above |
| Nonlinearity |
Within??0.05% RO |
| Hysteresis |
Within??0.05% RO |
| Repeatability |
0.05% RO or less |
| Rated Output |
1.5mV/V (3000??m/m) ??0.2% |
| Environmental Characteristics |
| Safe Temperature Range |
FH : -10 to 150??C (Excluding connector part) |
| FL : -200 to 80??C (Excluding connector part)
|
| Compensated Temperature Range |
FH : -10 to 150??C (Excluding connector part) |
| FL : -196 to 30??C (Excluding connector part) |
| Temperature Effect on Zero Balance |
Within ??0.005%RO/??C |
| Temperature Effect on Output |
Within??0.001%/??C |
| Electrical Characteristics |
| Safe Excitation Voltage |
20 VAC or DC |
| Recommended Excitation Voltage |
1 to 10V AC or DC |
| Input Resistance |
350???0.5% |
| Output Resistance |
350???0.5% |
| Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
5mm diameter by 5m long, terminated with connector plug. |
| (Shield wire is not connected to mainframe.) |
| Mechanical Properties |
| Safe Overload Rating |
200% |
| Critical Lateral Load |
500% |
| Natural Frequency |
See table above |
| Weight |
See table above |