LCH-F
Can Measure Compression Loads with 1/5000 Accuracy.
Useable in high humidity.
?? Remote sensing possible
?? Watertight structure
| Model |
Rated Capacity |
Natural Frequency
(Approx.) |
Weight
(Approx.) |
Movable
Saddle |
| LCH-10TF |
100kN |
7.5kHz |
12kg |
ER-10B |
| LCH-20TF |
200kN |
7kHz |
17kg |
--- |
| Performance |
| Rated Capacity |
See table above |
| Nonlinearity |
Within??0.02% RO |
| Hysteresis |
Within??0.02% RO |
| Repeatability |
0.02% RO or less |
| Rated Output |
2 mV/V (4000??m/m) ??0.1% |
| Environmental Characteristics |
| Safe Temperature Range |
-35 to 80??C |
| Compensated Temperature Range |
-10 to 60??C |
| Temperature Effect on Zero Balance |
Within ??0.0015% RO/??C |
| Temperature Effect on Output |
Within ??0.001%/??C |
| Electrical Characteristics |
| Safe Excitation Voltage |
20 VAC or DC |
| Recommended Excitation Voltage |
1 to 10 VAC or DC |
| Input Resistance |
350???0.5% |
| Output Resistance |
350???0.5% |
| Cable |
6-conductor (0.5 mm 2 ) chloroprene shielded cable,
9.5 mm diameter by 5 m long, with press-fit terminal for 4 mm |
| (Shield wire is not connected to mainframe.) |
| Mechanical Properties |
| Safe Overload Rating |
200% |
| Natural Frequency |
See table above |
| Weight |
See table above |
| Protection Rating |
IP67 (watertight type conforming to JIS C 0920) |