  • BFD-A-TS

    For stress measurement of reinforcing bar

    The BFD-A-TS series transducers are designed for stress measurement of reinforcing bars whose nominal diameters are larger than those measured by the BF-CT series. The BFD-A-TS series is used by welding both ends to a reinforcing bar in the field. Select the model suitable for the diameter of the reinforcing bar. Each model provides a temperature measuring function to enable simultaneous measurement of stress and temperature.
    Features
    ?? For long-term stable measurement, the transducer proper features a special structure
        with inert gas filled in.
    ?? The self-temperature-compensated strain gage used for the transducer enables measurement
        of temperature stress of the reinforcing bar.
    PDF Download
    Specifications
    Model ??A d??Deformed bar??
    BFD-A-35TS 60.5 D35
    BFD-A-38TS 63.5 D38
    BFD-A-41TS 70.0 D41
    BFD-A-51TS 76.3 D51

    Performance
    Rated Capacity 300MPa(1MPa??1N/mm 2 )
    Nonlinearity Within ??1% RO
    Hysteresis Within??1.5% RO
    Rated Output 1.85 mV/V (3700 ??m/m) or more
    Temperature Measurement
    Rated Capacity -30 to 70 ??C
    Measurement Error ??0.5??C (-30 to 70??C)
    (Refer to Small-Sized Temperature Transducer BTS-100AT)
    Environmental Characteristics
    Safe Temperature Range -30 to 80??C
    Compensated Temperature Range -10 to 70??C
    Temperature Effect on Zero Balance Within??0.1%RO/??C
    Temperature Effect on Output Within??0.1%/??C
    Electrical Characteristics
    Safe Excitation Voltage 10V AC or DC
    Input Resistance (at 0??C) 350 ?? ??2%
    Output Resistance (at 0??C) 450 ?? ??2%
    Cable 4-conductor (0.5 mm 2 ) chloroprene shielded cable,
    8 mm diameter by 1 m long, bared at the tip
    Mechanical Properties
    Safe Overload Rating 110%
    Nominal Diameter (Deformed Bar) See table above
    Material

    Metallic Finish

    Other
    Applicable Reinforcing Bar SD345 (formerly, SD35)
    Reinforcing Bar Please provide Reinforcing Bar for BFD-A-51TS to Magus
    2 pieces x 335mm long
    Calibration The BFD-A-51TS is calibrated by applying to a single
    sensing section, compressive load (approx. 600 kN) equivalent to the
    rated capacity of 300 MPa and compressive load (approx. 670 kN)
    equivalent to the safe overload rating