BR-BT
Enables measure concrete stress directly as stress and not via strain
A temperature measuring function enable them to measure stress and temperature simultaneously.
?? Theoretically backed performance of direct concrete stress measurement
with no conversion from a detected strain quantity.
?? Receive minimal effects of creep and changing elastic modulus of concrete.
and there by ensure accurate stress measurement.
?? Also usable for stress measurement of the natural ground by installing
at the rear of a tunnel lining.
Model |
Rateed Capacity |
BR-20KBT |
2MPa |
BR-50KBT |
5MPa |
BR-100KBT |
10Mpa |
* Models providing smaller rated capacities (200 kPa, 500 kPa, and 1 MPa)
manufactured on option.
Performance |
Nonlinearity |
Within ??1% RO |
Hysteresis |
Within??0.5% RO |
Rated Output |
??1mV/V(??2000??m/m) or more |
Temperature Measurement |
Rated Capacity |
-30 to 70 ??C |
Temperature Measurement Error |
??0.5 ??C(-30 to 70 ??C) |
(Refer to Small-Sized Temperature Transducer BTS-100AT) |
Environmental Characteristics |
Safe Temperature Range |
-30 to 80??C |
Compensated Temperature Range |
-20 to 70??C |
Temperature Effect on Zero Balance |
Within??0.05%RO/??C |
Temperature Effect on Output |
Within??0.05%/??C |
Electrical Characteristics |
Safe Excitation Voltage |
2 to 10V AC or DC |
Input Resistance (at 0??C) |
350 ?? ??1% |
Output Resistance (at 0??C) |
450 ?? ??0.8% |
Cable |
4-conductor (0.5 mm 2 ) chloroprene shielded cable, |
8 mm diameter by 1 m long, bared at the tip |
Mechanical Properties |
Safe Overload Rating |
150% (120% for 100KBT) |
Weight |
Approx. 2.9??kg |
Material |
Metallic Finish |