TP-CB
For measurements of high torque levels
Transducer for measurement of high torque levels such as ??2kNm or 5kNm. The CB type is a mounted type that has mounting legs fitted to the AB type in order that that shaft center alignment is easy. This is useful when installation accuracy is required, such as in vehicle output tests.
For measurement, a carrier type dynamic strain amplifier DPM is recommended.
?? Small impact from shaft bending or sliding
?? Mounting legs is available
Model |
Rated Capacity |
Maximum ROtational Speed (rpm) |
Angle of Torsion (rated) (Approx.) |
Torsion Spring Constant (Approx.) (Nm/rad) |
Inertia Moment Approx. (kg・m2 ) |
Allowable Thrust Load (Approx.)(N) |
Allowable Axial Load (Approx.)(N) |
Weight (Approx.) |
TP-200KMCB |
2kN・m |
3000 |
0.012rad |
166667 |
160x10-4 |
1500 |
400 |
42kg |
TP-200KMCB |
2kN・m |
3000 |
0.012rad |
166667 |
160x10-4 |
1500 |
400 |
42kg |
Performance |
Rated Capacity |
See table above |
Nonlinearity |
Within ??0.2% RO |
Hysteresis |
Within ??0.2% RO |
Rated Output |
1.5mV/V (3000??m/m)??0.2% |
(500KMCB:??0.5%) |
Environmental Characteristics |
Safe Temperature Range |
0 to 60 o C |
Compensated Temperature Range |
0 to 60 o C |
Temperature Effect on Zero Balance |
Within??0.01% RO/??C |
(500KMCB: within??0.05%RO/ o C) |
Temperature Effect on Output |
Within??0.03%/??C |
Electrical Characteristics |
Recommended Excitation Voltage |
1 to 6V AC or DC |
Input Resistance |
350?? ??0.5% |
Output Resistance |
350?? ??0.5% |
Cable |
4-conductor (0.3mm 2 ) chloroprene shielded cable,10m diameter by 7.6 m long, terminated with connector plug at both ends |
(Shield wire is not connected to mainframe.) |
Mechanical Properties |
Safe Overload Rating |
120% |