The Advanced Technical Solutions Consulting Group
Site Search
Product
ASHT-A

Compact and lightweight measure 3 axes acceleration simultaneously. * TEDS-installed versions can be manufactured. Inquires are welcome.
Features
▶ Measurement from DC is possible
▶ 3 acceleration transducers are within the same case, enabling measurement in X, Y, and Z axes.
▶ Minimal mutual interference between each axis, enabling high-accuracy measurement.
▶ Applicable to the analysis of acceleration in complex vibration phenomena
▶ Compact and lightweight
PDF Download
Specifications
Model Rated Capacity
(Reference Value)
Frequency Response
(at 23°C )
ASHT-A-100 ±980.7m/s 2 (±100G) DC to 1.2kHz Sensitivity
Deviation:±5%
ASHT-A-200 ±1961m/s 2 (±200G) DC to 2.1kHz Sensitivity
Deviation: ±5%
ASHT-A-500 ±4903m/s 2 (±500G) DC to 3kHz  Sensitivity
Deviation: ±10%
ASHT-A-1K ±9807m/s 2 (±1000G) DC to 5kHz  Sensitivity
Deviation: ±10%
Performance
Rated Capacity See table above
Nonlinearity Within±0.1% RO
Hysteresis Within±0.1% RO
Rated Output 0.5mV/V (1000μm/m) ±20%
Environmental Characteristics
Safe Temperature Range -15 to 65°C
Compensated Temperature Range 5 to 40°C
Temperature Effect on Zero Balance Within ±1%RO/°C
Temperature Effect on Output Within ±1%/°C
Electrical Characteristics
Safe Excitation Voltage 6V AC or DC
Recommended Excitation Voltage 2V AC or DC
Input Resistance 120Ω±8.3%
Output Resistance 120Ω±8.3%
Cable 4-conductor (0.08mm 2 ) vinyl shielded cable diameter
3.2 mm by 5 m long, terminated with connector plugs (3 pieces)
(Shield wire is not connected to mainframe.)
Mechanical PropertiesConnector
Safe Overload Rate 300%
Frequency Response Range See table above
Transverse Sensitivity 2% or less
Weight Approx. 45g (Approx. 420g including cable)
Dimensions 30×38×16mm