Special Design for Jacks,Low Price Various Capacity Ranges
LUR-B-SA1 series load cells are designed to measure loads applied to jacks when lifting up or moving a large machinery or structure in civil engineering and construction fields. These load cells enable the operators to prevent overloads, unbalanced loads, or movement of the center of gravity.
Model |
Rated Capacity |
Weight(Approx.) |
LUR-B-10KNSA1 |
??10kN |
1.4kg |
LUR-B-20KNSA1 |
??20kN |
2.1kg |
LUR-B-30KNSA1 |
??30kN |
2.2kg |
LUR-B-50KNSA1 |
??50kN |
LUR-B-100KNSA1 |
??100kN |
2.5kg |
LUR-B-200KNSA1 |
??200kN |
5.2kg |
LUR-B-300KNSA1 |
??300kN |
8kg |
LUR-B-500KNSA1 |
??500kN |
15kg |
LUR-B-1MNSA1 |
??1MN |
55kg |
LUR-B-1.5MNSA1 |
??1.5MN |
85kg |
LUR-B-2MNSA1 |
??2MN |
100kg |
LUR-B-3MNSA1 |
??3MN |
170kg |
LUR-B-5MNSA1 |
??5MN |
300kg |
With the capacity of 200 kN or more, calibration is performed for compression load only.
Performance |
Rated Capacity |
See table above |
Nonlinearity |
Within??0.2% RO (LUR-B-10 to 200KNSA1 )
Within??0.5% RO (LUR-B-300KNSA1 to 5MNSA1) |
Hysteresis |
Within??0.2% RO (LUR-B-10 to 200KNSA1 )
Within??0.5% RO (LUR-B-300KNSA1 to 5MNSA1) |
Rated Output |
??1 mV/V (2000??m/m)??1% |
Environmental Characteristics |
Safe Temperature Range |
-10 to 60??C |
Compensated Temperature Range |
0 to 60??C |
Temperature Effect on Zero Balance |
Within??0.01% RO/??C |
Temperature Effect on Output |
Within??0.01%/??C |
Electrical Characteristics |
Safe Excitation Voltage |
15V AC or DC |
Recommended Excitation Voltage |
1 to 10V AC or DC |
Input Resistance |
350???2% |
Output Resistance |
350???2% |
Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
7.6 mm diameter by 10 m long, terminated with connector plug |
(Shield wire is not connected to mainframe.) |
Mechanical Properties |
Safe Overload Rating |
200% |
Weight |
See table above(not including cable) |