MAGUS
제품문의
기술문의
Product
  • Strain Gages
  • Transducers
  • Load cells
  • Pressure Transducers
  • Acceleration Transducers
  • Torque Transducers
  • Displacement Transducers
  • Civil Engineering Transducers
  • Robot Test Systems
  • Precision Laser Scanners
  • Automotive Test Equipments
  • EuroNcap Test Dummy
  • Data Acquisition Systems
  • GPS/INS (Inertial Navigation Systems)
  • Fuel Consumption
    Testing Systems
  • Kinematics & Compliance
  • NVH Systems
  • Laboratory Test Systems
  • LCW-C-SA3

    Thin??High Stability Wide Range of Rated Capacities

    Extremely simple structure facilitates handling and maintenance. Widely applicable for bolt tension control, press forming, etc.
    Specification
    Model Rated Capacity Weight(Approx.)*
    LCW-C-10KN25SA3 10kN 0.6kg
    LCW-C-10KN35SA3 0.7kg
    LCW-C-10KN45SA3 0.8kg
    LCW-C-10KN55SA3 0.9kg
    LCW-C-10KN65SA3 1.0kg
    LCW-C-20KN25SA3 20kN 0.6kg
    LCW-C-20KN35SA3 0.7kg
    LCW-C-20KN45SA3 0.8kg
    LCW-C-20KN55SA3 0.9kg
    LCW-C-20KN65SA3 1.0kg
    LCW-C-50KN30SA3 50kN 1.7kg
    LCW-C-50KN40SA3 1.9kg
    LCW-C-50KN50SA3 2.1kg
    LCW-C-50KN60SA3 2.3kg
    LCW-C-50KN70SA3 2.5kg
    LCW-C-50KN80SA3 2.7kg
    LCW-C-100KN30SA3 100kN 1.7kg
    LCW-C-100KN40SA3 1.9kg
    LCW-C-100KN50SA3 2.1kg
    LCW-C-100KN60SA3 2.3kg
    LCW-C-100KN70SA3 2.5kg
    LCW-C-100KN80SA3 2.7kg
    LCW-C-200KN60SA3 200kN 3.7kg
    LCW-C-200KN70SA3 4.1kg
    LCW-C-200KN80SA3 4.4kg
    LCW-C-200KN90SA3 4.8kg
    LCW-C-200KN100SA3 5.1kg
    LCW-C-300KN60SA3 300kN 3.7kg
    LCW-C-300KN70SA3 4.1kg
    LCW-C-300KN80SA3 4.4kg
    LCW-C-300KN90SA3 4.8kg
    LCW-C-300KN100SA3 5.1kg
    Performance
    Rated Capacity See table above
    Nonlinearity Within??1% RO
    Hysteresis Within??1% RO
    Rated Output Approx. 1 mV/V (2000??m/m)
    Environmental Characteristics
    Safe Temperature Range -35 to 80??C
    Compensated Temperature Range -10 to 70??C
    Temperature Effect on Zero Balance Within??0.01% RO/??C
    Temperature Effect on Output Within??0.01%/??C
    Electrical Characteristics
    Safe Excitation Voltage 15V AC or DC
    Recommended Excitation Voltage 1 to 10V AC or DC
    Input Resistance 350???1%
    Output Resistance 350???1%
    Cable 4-conductor (0.3 mm 2 ) chloroprene shielded cable,
    7.6 mm diameter by 5 m long, bared at the tip
    (Shield wire is not connected to mainframe.)
    Mechanical Properties
    Safe Overload Rating 150%
    Weight See table above
    PDF Download
    Back to top
    Inquiries from the Web

    Inquiry(sales@magus.kr)

    Support(support@magus.kr)

    Quotations

    Orders

    Catalog Request