MAGUS
제품문의
기술문의
Product
  • Strain Gages
  • Transducers
  • Load cells
  • Pressure Transducers
  • Acceleration Transducers
  • Torque Transducers
  • Displacement Transducers
  • Civil Engineering Transducers
  • Robot Test Systems
  • Precision Laser Scanners
  • Automotive Test Equipments
  • EuroNcap Test Dummy
  • Data Acquisition Systems
  • GPS/INS (Inertial Navigation Systems)
  • Fuel Consumption
    Testing Systems
  • Kinematics & Compliance
  • NVH Systems
  • Laboratory Test Systems
  • LCTB-A

    Advanced Thin Design. Compared to the Conventional Load Cell, the Height is 1/2 to 1/3 Enabling a Wider Range of Applications.

    Features
    ?? Optional dedicated rubber attachment enables fixing the top and bottom with bolts,
        thereby making it possible to design the system with no tension rod or stay rod used.
    ?? Safety factor is 3 to 5 times higher than conventional type.
        Endures lateral loads up to 20% of the rated capacity.
    ?? Rubber attachment attenuates impact energy and lessens
        the effects of thermal expansion of system and the moment of fixed section.
    ?? Rubber attachement enables easy installation without concern for parallelism.
    ?? Varieties of accuracies and outputs are available,
        enabling configuration of the most suitable system for each application.
    ?? Peripheral instruments such as amplifiers can easily be connected since
        the wirings are the same as conventional load cells.

    *TEDS-installed versions can be manufactured. Inquiries  are welcome.
    PDF Download
    Specifications
    Model Rated Capacity Weight(Approx.)
    LCTB-A-5KN 5kN 1.8kg
    LCTB-A-10KN 10kN
    LCTB-A-20KN 20kN 2.3kg
    LCTB-A-30KN 30kN 4.3kg
    LCTB-A-50KN 50kN 5.3kg
    Performance
    Rated Capacity See table above
    Nonlinearity Within ??0.3%RO
    Hysteresis Within ??0.3%RO
    Repeatability 0.02% RO or less
    Rated Output 1.5mV/V (3000??m/m) ??0.2%
    Environmental Characteristics
    Safe Temperature Range -20 to 70??C
    Compensated Temperature Range -10 to 60??C
    Temperature Effect on Zero Balance Within??0.005% RO/??C
    Temperature Effect on Output Within ??0.005%/??C
    Electrical Characteristics
    Safe Excitation Voltage 20V DC
    Recommended Excitation Voltage 1 to 10V DC
    Input Resistance 350???1.5%
    Output Resistance 350???1.5%
    Cable 4-conductor (0.3 mm 2 ) chloroprene shielded cable,
    6 mm diameter by 5 m long, terminated with connector plug
    Mechanical Properties
    Safe Overload Rating 150%
    Critical Lateral Load 50% (maximum load which does not cause any mechanical damage)
    Weight See table above
    Material Aluminum alloy
    Back to top