LMR-S-SA2
Compact,Lightweight, Low price, Suitable for Load Distribution Measurement
Compact and lightweight LMR-S-SA2 series load
cells can be used by merely putting or bonding on the
subject site or setting in a hollow. Major applications
include measurement of load distribution by using
multiple units, load measurement in pipe making mill
or where a measuring site or the weight of load cell
itself is limited.
* TEDS-installed versions can be manufactured. Inquiries are welcome.
Model |
Rated Capacity |
LMR-S-2KNSA2 |
2kN |
LMR-S-5KNSA2 |
5kN |
LMR-S-10KNSA2 |
10kN |
LMR-S-20KNSA2 |
20kN |
*Users should be cautioned that operating conditions may adversely affect the
stated specifications. |
Performance |
Rated Capacity |
See table above |
Nonlinearity |
Within ??1% RO (LMR-S-2KNSA2 to 10KNSA2)
Within ??2% RO (LMR-S-20KNSA2) |
Hysteresis |
Within ??1% RO (LMR-S-2KNSA2 to 10KNSA2)
Within ??2% RO (LMR-S-20KNSA2) |
Repeatability |
??1% RO or less |
Rated Output |
1 mV/V (2000 ??m/m) or more |
Environmental Characteristics |
Safe Temperature Range |
-10 to 60??C |
Compensated Temperature Range |
0 to 50??C |
Temperature Effect on Zero Balance |
Within ??0.05% RO/??C |
Temperature Effect on Output |
Within ??0.05%/??C |
Electrical Characteristics |
Safe Excitation Voltage |
7V AC or DC |
Recommended Excitation Voltage |
1 to 5V AC or DC |
Input Resistance |
350???2% |
Output Resistance |
350???2% |
Cable |
4-conductor (0.035 mm 2 ) vinyl shielded cable,
1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is connected to mainframe.) |
Mechanical Properties |
Safe Overload Rating |
120% |
Natural Frequency |
Approx.50kHz |
Weight |
Approx.25g |
Material |
Stainless steel |